|
|
 |
 |
Signal Conditioning Channels
View our Charts for:
Signal Modules for D20 - D200 - GSR20 - GSR200 - D5000
Signal Modules for A Series Recorders

Dxx Series Signal Modules

Axx Series Signal Modules |
Axx and Dxx Series Signal Modules
All of our recorders can be fitted with a range of plug-in modules to provide self-contained signal conditioning. Each module's input and output parameters have convenient calibration ranges for ease of configuration. Channel set-up is simply achieved through the front panel display, a PC computer interface or an optionally available remote control. The complete channel and system configuration is also recorded on tape to facilitate subsequent data identification and the required reproducer configuration. To provide acquisition confidence, the recorder and modules are constantly monitored for channel overloads, data errors and malfunctions.
A wide variety of signal conditioning modules including analog, digital, video, communications, automotive bus and avionics bus interfaces are provided to tailor a system to specific data acquisition requirements.
Axx Signal Modules (537kb pdf)
Dxx Signal Modules (759kb pdf)
|
|
SERIES '40' SIGNAL MODULES FOR D20 - D200 - GSR20 - GSR200 - D5000
| Type |
Channels |
Application |
| ANH40 |
1 Record & Replay |
General purpose high bandwidth analog recording and reproduction. 16 or 8 bit resolution. |
ANR41/
ANP41 |
8 Record/
8 Replay |
General purpose medium bandwidth analog recording and reproduction. 16 bit resolution. |
| DCM40 |
1 Record & Replay |
Medium speed serial PCM recording and replaying with a wide variety of clock and code modes. Chapter 10 throughput mode only. |
| PCM40 |
1 Record & Replay |
High speed serial PCM recording and replaying with a wide variety of clock and code modes. Synch word recognition and frame synchronization. |
| MRG40 |
8 Record or Replay |
Compact, medium speed serial PCM recording or replaying with a wide variety of clock and code modes. |
| ETH40 |
2 Record & Replay |
Ethernet bus communications capture. Records the complete bus in monitor mode. |
DCR40/
DCP40 |
1 Record/
1 Replay |
Replacement of DCRsi recorders and reproducers to operate with legacy multiplexers etc. |
UAR40/
UAP40 |
4 Record/
4 Replay |
Compact MIL-STD-1553 recording or replaying of 4 dual redundant or 8 individual busses. |
| UAR80 |
8 Record |
Ultra-compact MIL-STD-1553 recording of 8 dual redundant busses. |
| ARR40 |
24 Record |
Ultra-compact high or low speed ARINC429 bus recording in monitor mode. Automatic speed sensing. |
| ARR41 |
16 Record |
Economic compact high or low speed ARINC429 bus recording in monitor mode. Automatic speed sensing. |
| VCR40 |
4 Record |
Flexible video acquisition with selectable MPEG conversion rates up to 15 Mbit/s per channel. Time overlay insertion available. |
| ASM40 |
16 Record or Replay |
Compact record or replay of serial communications. |
| GPS40 |
0 |
GPS receiver, range time acquisition, synchronization and distribution for high velocity platforms. |
| GPS12 |
0 |
GPS receiver , economic range time acquisition, synchronization and distribution. |
SERIES '12' SIGNAL MODULES FOR D20 - D200 - GSR20 - GSR200 - D5000
| Type |
Channels |
Application |
ANR20/
ANP20 |
8 Record/
8 Replay |
General purpose low bandwidth analog recording and reproduction.16 bit resolution. |
| DCM12 |
1 Record & Replay |
Medium speed serial PCM recording with a wide variety of clock and code modes. |
| DCB12 |
1 Record & Replay |
Similar to DCM12 and can retain the timing and duration of intervals between burst data when data timing is relevant. |
| MRG12 |
4 Record & Replay |
Compact low speed serial PCM recording. |
| MRB12 |
4 Record & Replay |
Similar to MRG12 and can retain the timing and duration of intervals between burst data when data timing is relevant. |
| PAR12 |
16 Record & Replay |
Parallel digital recording of 2, 4, 8 or 16 bits. Suitable for low speed parallel and status information. |
| ASM12 |
8 Record & Replay |
Compact method of recording multiple independent asynchronous serial data communication lines. |
ARR12/
ARP12 |
8 Record/
8 Replay |
High or low speed ARINC429 busses in monitor mode. Automatic speed sensing. Replay as reconstructed bus. |
MBR12/
MBP12 |
2 Record/
2 Replay |
2 full Dual Redundant MIL-1553 busses as monitors. Replay as the reconstructed busses. |
RSR12/
RSP12 |
4 Record/
4 Replay |
Total bus record and replay of the RSB Bus [Honeywell ASCB] in monitor mode. |
CSR12/
CSP12 |
2 Record/
2 Replay |
High or low speed CSDB Bus recording as a monitor. Automatic bus speed identification. |
VCR12/
VCP12 |
2 Record/
2 Replay |
Flexible video acquisition with selectable MPEG conversion rates up to 20 Mbit/s. |
| VSM12 |
2 + 1
Record & Replay |
Voice annotation and low rate serial auxiliary data. |
| IRR12 |
2 replay |
Replays 2 dual redundant MIL-1553 bus recordings as IRIG-106 Chapter 8 PCM data streams. |
| BBM20 |
0 |
Provides seamless back up power during supply variations and disruptions. Integral and external chargers. |
| DBM12 |
0 |
Blanks out one module slot. All module slots must be filled to ensure correct thermal circulation and dust exclusion. |
In general, for IRIG106 Chapter10 applications use Series 40 signal modules. VSM12, MBP12, ARP12, VCP12 are Chapter 10 compatible.
DCRsi is a trade mark of AMPEX DATA SYSTEMS CORPORATION
Signal Modules for A Series Recorders
| Type |
Channels |
Application |
| |
|
Frequency shown is single channel maximum bandwidth; lower analog bandwidth is user selectable in 1 Hz increments. Analog sampling is 16 bit resolution unless stated otherwise. Analog range shown is maximum; lower ranges user selectable. Bit rate shown is single channel maximum and is automatically synchronized to incoming clock.
|
| DIC20 |
2 Record |
Economical analog recording with built in constant current source for IEPE sensors. 25 kHz, 10 Vp |
| MIC20 |
2 Record |
Recording from calibrated microphones such as the B&K range. Provides pre-amplifier and polarization power. Optional high pass filters. 25 kHz. |
| CHG20 |
2 Record |
Suitable for charge coupled devices. Optional low pass filter. 25 kHz. Up to 10,000 PC. |
| CHG21 |
2 Record |
Suitable for charge coupled devices. Selectable high pass filter. Optional low pass filter. 25 kHz. Up to 100,000 PC. |
| SGC21 |
2 Record |
Strain gage measurement suitable for full, half and quarter bridges. Selectable low pass filter. Remote shunt calibration. Integral bridge supply with auto-balance. 45 kHz. 10 Vp. |
| DIC21 |
2 Record |
Analog channel with AC,DC and IEPE inputs. 50 V DC offset capability. Ideal for shaft rotation sensors. 45 kHz, 100 Vptp. |
| DIC61 |
6 Record |
Compact analog channel for high channel count systems (e.g. 2 tri-axial sensors in one module). AC, DC and IEPE inputs. TEDS smart sensor identification. 45 kHz. 10 Vrms. |
| HSI10 |
1 Record |
High analog bandwidth capability with single ended and differential inputs. 200 kHz. 5 Vp. |
| DCM20 |
1 Record & Replay |
Serial PCM record and replay for NRZ and Bi-phase data. RS422 and single ended I/O. 4 Mbit/s. |
| PAR20 |
16 Record & Replay |
Parallel digital recording suitable for low rate serial, parallel and status data. 2, 4, 8 or 16 bit mode. 840 kHz (2 bit). |
| RPM20 |
2 Record |
Suitable for recording pulses from shaft rpm sensors through galvanically isolated inputs. 60 through 12,000 rpm measurement range. 100 kHz. |
| EBU20 |
2 Record & Replay |
Transparent recording of the 16 MSB of AES/EBU audio bus via galvanically isolated inputs. |
| CAN10 |
1 Record |
Transparent CAN bus recording via opto-coupler. 1 Mbit/s. |
| OUT20 |
2 Replay |
Analog signal reconstruction for all analog recordings up to 25 kHz bandwidth. 5 Vp. |
| OUT61 |
6 Replay |
Analog signal reconstruction for all analog recordings up to 45 kHz bandwidth. 5 Vp. |
| OUT80 |
8 Replay |
Analog signal reconstruction for all analog recordings up to 25 kHz bandwidth. 10 Vrms. |
| HSO10 |
1 Replay |
Analog signal reconstruction for all bandwidths from 28 kHz through 200 kHz. 5 Vp. |
ABP20, ABP30, ABP60 |
0 |
Blanking panels, 2 3 and 6 slots wide |
| ABM20 |
0 |
Blanking module. |
|
|